Precast OSD
Modular System

Pro-Cast's product
Product Overview

MEGATRAP Precast OSD Modular System for Stormwater Detention

An on-site detention (OSD) system stores stormwater runoff on a development site and releases it slowly, so the peak flow into public drains does not increase after the site is built. Pro-Cast’s MEGATRAP OSD Modular System is an underground tank made from high-strength precast concrete modules, each 2.4 m × 4.0 m, placed side by side to form a larger tank under car parks, access roads or landscaped areas.

In Malaysia, OSD design follows the Urban Stormwater Management Manual for Malaysia (MSMA) published by the Department of Irrigation and Drainage (JPS). Our modules can be arranged to match the storage volume your engineer calculates under MSMA.

Key Fact

System
MEGATRAP precast reinforced concrete modules, assembled underground
Module footprint
2400 × 4000 mm
Module heights
1.5, 2, 2.5, 3, 3.5 and 4 m; single or double (stacked) modules
Uses
detention tank, retention tank, or combined detention and retention
Loading
designed to carry vehicle traffic above the tank
Design basis
MSMA

How a Precast
OSD System Works

01. Collect

Runoff from roofs, roads and paved areas flows through drains into the OSD tank.

02. Store

The precast modules hold the water during heavy rain, when public drains are under the most pressure.

03. Release

A controlled outlet lets water leave the tank slowly, keeping discharge within the allowed limit.

MEGATRAP Module
Specifications

Dimension Value
Module width 2400 mm
Module length 4000 mm
Wall opening width (w1) 450 mm
Slab thickness (t1) 150 mm
Module heights 1.5, 2, 2.5, 3, 3.5, 4 m
Internal columns 200 × 200 mm RC columns
Walls 175 mm thick
Module types A to E (corner, edge and internal modules, combined in a grid)
Joints Joint wrap between modules
Tank capacity Designed per project, typically 100–3,000 m³
Modules combine like building blocks into a layout that fits the available space, and customised designs are available for specific projects.
Applications

Where Precast OSD Systems Are Used

01. Detention tanks

Hold runoff and release it slowly to meet the allowed discharge.

02. Retention tanks

Store water on sitefor reuse.

03. Combined detention and retention tanks

Both functions in one system.

Typical sites: housing developments, commercial and industrial sites, data centres and institutional buildings, especially where land is limited and the tank must sit under parking or roads.

Why Choose the MEGATRAP OSD Modular System

  • Saves land.
    The tank sits underground, beneath parking areas, access roads or landscaping, so the surface stays usable.
  • Fits tight sites.
    Modules combine in flexible layouts to fit the space available.
  • Carries vehicle traffic.
    Designed for traffic loading above the tank.
  • Quick installation.
    Factory-made modules are placed and joined on site, with no formwork or curing for the tank walls.
  • Easy maintenance access.
    Designed for long-term inspection and cleaning.
  • Flexible depth.
    Six module heights from 1.5 m to 4 m, single or double, to suit site area and depth.

Precast OSD vs
Cast-in-Situ OSD Tank

Precast OSD saves site time because the tank is made in a factory; a cast-in-situ tank is built entirely on site.

Precast OSD modular system Cast-in-situ OSD tank
Construction Modules made in factory, assembled on site Formwork, rebar and concrete poured on site
Site time Shorter: no curing time for tank walls on site Longer: each pour needs time to cure
Quality control Factory-controlled Depends on site conditions and workmanship
Weather impact Lower Rain can delay concreting
Capacity changes Add or remove modules Redesign and rebuild

Precast OSD FAQ

What is an OSD system?

An on-site detention (OSD) system is a storage facility, usually an underground tank, that holds stormwater runoff from a development and releases it slowly through a controlled outlet. It stops new developments from increasing the peak flow into public drains, which helps reduce flash flooding downstream.

Many new developments in Malaysia must provide stormwater control designed to the Urban Stormwater Management Manual for Malaysia (MSMA), and OSD is a common way to meet it. The exact requirement depends on the local authority and the development, so check with your engineer and the approving authority.

The required storage volume is calculated by the project’s engineer using MSMA methods, based on site area, rainfall data and the allowed discharge. Pro-Cast then configures the number and layout of MEGATRAP modules to provide that volume.

Precast OSD modules are made in a factory and assembled on site, so installation is faster, less affected by rain, and more consistent in quality. A cast-in-situ tank needs formwork, rebar fixing and curing on site, which takes longer and depends more on site workmanship.

Yes. The MEGATRAP OSD Modular System is designed to carry vehicle traffic loading, so the area above can be used for car parks, access roads or landscaping. 

Each MEGATRAP module has a 2400 × 4000 mm footprint and comes in heights of 1.5, 2, 2.5, 3, 3.5 and 4 m. Modules can be used singly or stacked as double modules, and placed side by side in a grid to reach the storage volume the project needs. Tank capacity is designed for each project, typically 100 to 3,000 m³.

Plan Your OSD
With Pro-Cast

Send us your required storage volume and site layout, and we will propose a module configuration and quotation.